Elitech WJL-6000 Refrigerant Halogen Leak Detector
Featuring with a corona sensor and advanced leak detect technology, WJL-6000 is our reliable product with the functions of easy operation, stable function and great performance; It’s an ideal and economic freon and halogen leak detector. It is widely applied on pipe leakage, automobile air conditioner, cold storage, refrigerator repair and so on.
Features:
Traditional Corona Sensor
It will respond to all halogenated. This includes, but is not limited to:
CFCs e.g.R12, R11, R500, R503 etc. HCFCs e.g. R123, R124,R502 etc. HFCs e.g. R134a, R404s, R125, R1234yf etc. Blends such as AZ-50. HP62. MP39 etc.
Short Preheating Time Once the switch rotated, the detector will be ready to use. Preheating time: 6s Response time: 3s
Notice: Wait for 6 seconds away from the potential leakage area once the leak detector is switched on for more accurate detection or it may not give right alarm when you try to detect.
7 Adjustable Sensitivity 1-7 Grade selectable sensitivity Maximum sensitivity is 0.21oz/yr smaller leak, higher sensitivity grade More refrigerants, more rapidly beeps, faster indicator flashes Note: 2 beeps per second when the detector is open, 10 beeps per second when leak is detected)
Features
Audible and Visual Alerts LED light flash alarm Buzzer alarm Dual-battery indicators
Green-the battery voltage is normal, suitable for the job.
Orange-the battery voltage is close to the limit work, need to be replaced asap.
Flexible Probe Around 7.87-inch flexible probe Allows detection in difficult and hard-to-reach areas.
4AAA Batteries Battery life: about 50 hours
Leak Detector equips with: Compact design Portable black bag to carry and storage Note: batteries NOT included
Technical Parameters
1.Operating temperature: 0℃-52℃ (30℉ to 125℉);
2.Maximum sensitivity: 0.21oz/yr,for all halogenated refrigerants;
3.Battery life:approximately 50 hours normal use;
4.Response time:Instantaneous ;
5.operating mode: continuous,no limitation;
6.Fixed probe length:7.87 (in);
7.Dimensions:1.37 x 1.37 x 5.90 in ;
8.Preheating time: approximately 6 seconds;
9.Reset time: two to ten seconds;
10.Power supply: 6V DC, 4 AAA alkaline batteries.
11. Package includes: 1 x Detector, 1 x Carry Bag, 1 x User Manual Product Overview:
For all halogen leak detectors in our shop, model wjl600,
cld100, hld100+, hld200+ are corona types; model LD-100 and LD-200 are semiconductor detectors. The sensitivity of semiconductor is higher, and
the lifetime of sensor is also longer. Main features:
• Detect all kinds of halogen refrigerant gases;
• Sensitivity adjusted at any time and it can be adjusted
automatically to the best state of detecting;
• Inner precise IC with ultra-low power consumption circuit
design, more stable, longer battery life;
• Dual-color visual display of battery voltage;
• Excellent sensor,high sensitivity,long lifetime. Applications:
The Elitech WJL-6000 Halogen Leak Detector may also be
used to:
It will respond to all halogenated (contains Chlorine of
Fluorine) refrigerants. This includes, but is not limited to:
CFCs e.g.R12, R11,R500,R503 etc. HCFCs e.g. R123, R124,R502
etc. HFCs e.g. R134a, R404s, R125 etc.
Blends such asAZ-50. HP62. MP39 etc.
Detect Ethylene Oxide gas leaks in hospital sterilizing
equipment (it will detect the halogenated carrier gas).
Detect SF-6 in high voltage circuit breakers.
Detect most gases that contain chlorine, fluorine and bromine
(halogen gases). Detect cleaning agents used in dry cleaning
applications such as per chloroethylene. Detect halogen gases
in fire-extinguishing system. Technical parameters:
•operating temperature: 0°C-52 °C (30°F to 125°F);
•Maximum sensitivity: 6 g/yr,for all halogenated refrigerants;
•Battery life:approximately 50 hours normal use;
•Response time:Instantaneous ;
•operating mode: continuous,no limitation;
•Fixed probe length: 20cm;
•Dimensions:22.9*6.5*6.5 (cm);
•warm-up time: approximately 6 seconds;
•Reset time: two to ten seconds;
•Power supply 6V DC, four AAA alkaline batteries. The battery voltage indicator:
The light on the front panel is used for leakage warning
instructions and battery voltage.
Green - the battery voltage is normal, suitable for the job
Orange - the battery voltage is close to the limit work, need
to be replaced as soon as possible Boot automatically reset/follow the circuit:
- WJL - 6000 is a boot and automatic reset function, halogen
gas levels can ignore the environment.
- Boot reset: the instrument after startup, can automatically
adjust circuit within 6 s to ignore probe existing
- Refrigerant concentration level, the state of detection,
users such as beside the leakage source boot, party
- Seeking higher concentration of leakage source. Instrument
can also be moved to clean up in the air, with adjustable
- Whole to maximum sensitivity, the above zero concentration
level of leakage can be detected.
- Automatic follow circuit: when the instrument is in a state
detection, automatic circuit will follow halide in the environment
- The change of gas concentration, to prevent false alarm. Package included:
· 1 x Detector
· 1 x Carry/storage case
· 1 x Instructions
Weight : 34.8lbs
Box dimension ( inch ) 23*16*15
Notice: Wait for 6 seconds away from the potential leakage area once the leak detector is switched on for more accurate detection or it may not give right alarm when you try to detect. WJL-6000 CLD-100 HLD-100+ HLD-200 LD-200 ILD-200 Sensor Type Corona Corona Corona Corona Heated Diode Advanced Battery included NO NO NO NO YES YES Battery Required 4 AAA 4 AAA 2 C 2 AA Li-1800mA/h Li-3000mA/h Sensor Life ≥ 24 hours ≥ 24 hours ≥ 24 hours ≥ 24 hours ≥ 500 hours ≥ 10 years Probe Length 7.87 inch 7.87 inch 13.98 inch 12.01 inch 14.37 inch 14.37 inch Rechargeable NO NO NO NO YES YES Sensing Tip 1 1 2 2 1 1 Shipping
We will ship all items within 3 working days once payment finished,
We always ship items by USPS First Class, FedEx is the Expedited Shipping choice.
Sometimes international's delivery is highly dependent on the courier company and local customs/duties.
Import duties and taxes are not included in the item price or shipping charges. These charges are the buyer responsibility. About us
How we got our start?
Elitech initiated in the HVAC field in 1996 as a global manufacturer. With our R&D center located in Silicon Valley, CA, Elitech has established subsidiaries all over the world.
What makes our product unique?
With over 26 years of HVAC products manufacturing experience, Elitech produces a complete line of HVAC tools, with additional refrigeration solutions, Elitech leads the new generation of smart HVAC tools.
Why we love what we do?
Our mission is to combine intelligence and innovation with the refrigeration industry and make all work easier.
Returns Accepted for this item if it's within 60 Days